λGEL DP Series ( Paste-type Thermal GEL )

λGEL DP Series ( Paste-type Thermal GEL )
DP Series are very soft and comformable paste type Thermal GEL.

Physical Characteristics

Item Paste-type Thermal GEL DP Series Remark
DP-100 DP-200 DP-300
Thermal
conductivity
(W/m · K)
Our tests 6.5 4.8 4.8 Taica std.
Hot Wire
Method*1
2.1 1.6 1.6 JIS R 2616
Appearance Gray paste Gray paste White paste -
Specific gravity 2.8 2.6 2.7 JIS K 6249
Hardness
(Cone penetration ·
1/10mm not mixed)
51 55 60 JIS K 6249
(1/4 cone)
Specific volume
resistance ratio
(Ω · cm)
5.9×1013 7.2×1014 1.4×1014 JIS K 6249
Dielectric
constant
〈50Hz〉 8.9 7.6 4.4 JIS K 6249
〈1kHz〉 7.8 6.7 4.2 JIS K 6249
〈1MHz〉 7.0 6.6 4.0 JIS K 6249
Dielectric
dissipation
factor
〈50Hz〉 0.234 0.017 0.005 JIS K 6249
〈1kHz〉 0.061 0.007 0.004 JIS K 6249
〈1MHz〉 0.015 0.005 0.0004 JIS K 6249
Dielectric breakdown
voltage (kV/mm)
5.0 5.6 9.6 JIS K 6249
Low
molecular
weight
siloxane
level
ΣD4 -
10(ppm)
Solvent
extraction
method
less than
700
less than
900
less than
300
-
Head
space
Method*2
less than
1
less than
3
less than
1
-
RoHS controlled
substances*3
Not detected Not detected Not detected -
Temperature range(℃)*4 -40 ~ +200 -40 ~ +150 -40 ~ +120 -
  Bottle  
*1
*2
*3
*4
Hot Wire Method : Using the QTM - 500 Quick Thermal Conductivity Meter, from Kyoto Electronics Manufacturing Co., LTD.
Head Space Method : at 70℃.
RoHS controlled substances : Assayed by SGS Far East Ltd.
Temperature range :
These temperature ranges are not the guaranteed values by Taica Corporation.
The applicability should be determined respectively through the tests under actual conditions of each usage.

The flow of heat

Applications

Filling example DP-100/REP-100
Coating example DP-200/DP-300

Delivery format

Basic specifications
DP-100,200 Syringe 30cc
DP-300 Bottle 30cc

*Other package is also available.

NOTE
  1. · Silicone oil may bleed under certain usage condition.
  2. · Low molecular siloxane is included in this product basically composed of silicone.

    To the best of our knowledge , the information and statements on this literature are believed to be true and reliable ;however, the PRODUCTS described herein are sold WITHOUT ANY GUARANTEE OR WARRANTY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSES since the application and conditions of each use vary and change, and are beyond the control of manufacture and seller(s).The customers and users of the PRODUCTS shall assume the responsibility for determining the suitability of the PRODUCTS based on their tests and for whatever risks and liability associated with the use of the PRODUCTS. NEITHER MANUFACTURER OR SELLER(S) SHALL BE LIABLE EITHER IN TORT OR CONTRACT OR ANY OTHER CAUSE FOR ANY KIND OF LOSS OF PROFITS OR DAMAGE , INCIDENTAL, DIRECT, OR CONSEQUENTIAL ARISING OUT OF OR IN CONNECTION WITH THE USE OF OR THE INABILITY TO USE THE PRODUCTS.

Please click Inquiry for further information.

*Taica® , αGEL® , OPTαGEL® , and the visual image of falling eggs are trademarks of Taica Corporation, registered in Japan,the United States and / or other countries.